CF1100 Intelligent Addressable 1 Loop Control Panel

KSh131,493.19

The CF1000VDS range is available as a high specification 1 or 2 loop intelligent addressable control panel, offering sophisticated functionality with simple end user operation. This addressable control panel offers a perfect fire alarm system for a small or medium fire safety projects. The simplicity of operation, powerful cause and effect programming capability and competitive pricing make the system suitable for a wide range of small to medium sized projects.

Description

The CF1000VDS range is available as a high specification 1 or 2 loop intelligent addressable control panel, offering sophisticated functionality with simple end user operation. This addressable control panel offers a perfect fire alarm system for a small or medium fire safety projects. The simplicity of operation, powerful cause and effect programming capability and competitive pricing make the system suitable for a wide range of small to medium sized projects.

Product Description/ Features/ Specifications


The CF1000VDS range is available as a high specification 1 or 2 loop intelligent addressable control panel, offering sophisticated functionality with simple end user operation.

The simplicity of operation, powerful cause and effect programming capability and competitive pricing make the system suitable for a wide
range of small to medium sized projects. CF1000VDS uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing.

These panels can operate as a stand alone panel or as part of a network with the Cooper range of CF3000 panels or other CF1000VDS panels (additional network card required).

The CF1000VDS range of panels have an integral power supply and are supplied with batteries as standard.

An extensive range of compatible intelligent addressable system ancillaries are available to work with the CF1000VDS range all of which incorporate an integral short circuit isolator to provide maximum protection against short circuit faults on the loop.

Features

  • Available in 1 and 2 loop versions
  • Up to 200 addresses per loop
  • Full network capability up to 126 panels
  • Soft addressing
  • Large versatile touch-screen user interface
  • Multi-language selection capability
  • Integral battery and power supply
  • Flexible cause and effect programming

Benefits

  • Simple to operate end user touch-screen interface
  • Flexible distributed network capability
  • Full range of compatible accessories
  • Easy to design system cause and effect using site installer software
  • Full system integrity with Cooper developed protocol

Compliant for the German market – VDS certified

Panel type CF1100VDS CF1200VDS
Standards EN54 Pt2,1997, A1:2006,
EN54 Pt4,1997 A1:2002,A2:2006,
EN54 Pt13: 2005
Number of loops 1 2
Addresses per loop 200
Panel sounder circuits 2
Auxiliary relay One set of change over contacts, operated in the event of fire activation
Auxiliary fire routing
equipment output
Monitored 24V dc, 30 mA (max)
Auxiliary fire protection
equipment output
Monitored 24V dc, 30 mA (max)
Auxiliary fault routing
equipment output
Monitored 12V dc, 30 mA (max)
Output ports RS485 and RS232 (for connection of repeaters etc)
Mains input voltage 230V ac +10% / -15%
System operating voltage 24V dc
Batteries 2 x 12V 7Ah
Standby duration 24 hours (subject to loop load)
Cable entries 11 top entry cable knockouts (20mm) plus rear entry cable aperture
Environmental rating IP30, -5ºC to +40ºC, 75% RH (non condensing)
Size WxHxD (mm) 375x357x50
Weight 8kg